BIONIME Rightest Blood Glucose Monitoring System | Diabetes
PRODUCTS > GM550 Series
GM550 Series

Feature

  • Fully comply with ISO 15197:2013 (For other received credentials, please contact us.)

  • LCD with backlight

  • Auto-coding

  • Only 0.75microliter (0.00075 c.c.) of blood sample required

Product Intro Specification Movie Q&A Downloads

The GM550 is a high-end model with many advanced functions. The feature of auto coding makes the meter easy to use. Backlight design enables people to read the test result even in the dark. With its accuracy & precision, the GM550 has attracted a lot of attentions from the professional users.

Measurement Technology Oxidase Electrochemical Sensor
Measurement Calibration Plasma
Sample Capillary whole blood
Minimum Sample Volume 0.75 µL
Measuring Range 10~600 mg/dL (0.6~33.3 mmol/L)
Test Time 5 seconds
Memory Capacity 500 blood glucose test results with data and time
Power Saving Tum off automatically 2 minutes after last user action/ Press the button for 4 seconds.
Operating Temperature 10~40℃ (50~104℉)
Operating Relative Humidity 10~90%
Hematocrit 30~60%
Power Supply 2 CR2032 batteries
Battery Life About 1,000 tests
Meter Dimension 90.6x46.0x16.5 mm
Meter Weight 53.0±5 g with batteries
Monitor LCD display
Display Area 47.0x33.5 mm
Meter Storage Conditions -10~60℃ (14~140℉)
Test Strip Storage Conditions 4~30℃ (39~86℉),<90% relative humidity

 


GM550 Video (Single)

GM550 Video (Multi)

Q1. How can I do if it cannot be switched on or doesn’t function?
1. Open the battery cover and taking off the batteries, press the main button for over 10 seconds, then put on new batteries to check if the meter can function.
2. Please switch on the meter after reloading new batteries, the type of battery for GM550 is two CR2302 coin cell batteries.
3. If the meter still doesn’t function, please contact with local distributor for further help.

Q2. How can I do if it keeps doing self-test running, and can’t switch to time setting mode when pressing the main button?
Please switch on the meter after reloading new batteries, the type of battery for GM550 is two CR2302 coin cell batteries.

Q3. How do I deal with the error message when showing “code error” on the screen?
1. Please check if the test strip port were contaminated or damaged, please insert the test strip to check if the meter can function and show blood symbol.
2. Open a new test vial and use test strip to insert the meter again to check if the meter can function.
3. Please leave the hand or finger off the strip after it inserts to the correct position.
4. Please store the meter in the carrying case when not use to prevent the meter from contaminated and keep the meter dry.
5. If the meter still doesn’t function, please contact with local distributor for further help.

Q4. What Er1 message means and how can I do?
1. The strip has been used or exposed to the air too long, please open a new strip vial and start a new test.
2. Please discard used strips, not put back into vial to prevent other un-used strips from contaminating.

Q5. How can I do if the meter showing ER2?
1. Open the battery cover and taking off the batteries, press the main button for over 10 seconds, then put on new batteries to check if the meter can function.
2. Please switch on the meter after reloading new batteries, the type of battery for GM550 is two CR2302 coin cell batteries.
3. If the meter still doesn’t function, please contact with local distributor for further help.

Q6. How can I do if the meter showing ER3?
When the meter starting to measure the blood glucose, the strips are moved or taking out, the screen shows Er3 due to signal disconnected.

Q7. How can I do if the meter showing ER4?
When dripping the sample, please be noted if the sample covers the whole of the view window. The sample size we suggest is 1.0μL~2.0μL, if below 1.0μL, the meter will show ER4.

Q8. How can I do if the testing result is inaccurate?
1. The test strip may absorb too much humidity due to expose to the air too long, which will cause the deterioration of test strip quality. Please close the strip vial immediately after taking out the test strip, and finish the test within 3 minutes to avoid test strip expose to the air for a long time.
2. If the testing results of the strips in the same vial are different, please do the quality control test.
3. Check if the “smart code key” were contaminated or has been contaminated, or the electrode is damaged, if yes, please contact with local distributor for further help.

Q9. How can I do if the result of the quality control test does not fall within the range on the strip vial?
1. When doing control test, after inserting a new strip, please press the main button for 5 seconds and the screen shows “CS” to enter control test mode; then dripping CS to do the test.
2. Please store the control solution in the carrying case and in general temp. and discard after 3 months after opening.
3. When doing the control te
st, please drop the control solution (CS) on the cap of the CS and drip from it, close the cap immediately after test; Please not drip control solution to the test strip directly to keep the quality of CS.
4. To prevent the quality of CS from being deteriorated, please close the cap immediately to avoid CS of exposing to the air.
5. If the test result were still inaccurate, please start a new test with a new open strip; if the problem can’t be solved, please contact with local distributor for further help.